TrueLok™ EVO
THIS INFORMATION IS FOR HEALTHCARE PROFESSIONALS ONLY
THIS INFORMATION IS FOR HEALTHCARE PROFESSIONALS ONLY
Distal tibia fracture treated TrueLok EVO™.
| Q.ty | Catalogue N. | Description |
|---|---|---|
| 1 | 99-88002
|
TRUELOK EVO SET RX RINGS D160MM RX STRUTS MEDIUM STERILE |
| 1 | 99-88020
|
TRUELOK EVO CONN ELEMENT K WIRES CYLINDR PINS SET STERILE |
| 2 | 99-882160
|
TRUELOK EVO RX 5/8 MODULAR RING D160MM STERILE |
| 3 | 99-886004
|
TRUELOK EVO RX STRUT MEDIUM WITH DYNA |
| 3 | 54-1216
|
TL,WIRE, BAYONET, 1.8MM X 400MM |
| 2 | 99-885001M
|
TRUELOK EVO WIRE FIXATION BOLT (PACK OF 4) |
| 2 | 99-885004
|
TRUELOK EVO 2 HOLES POST |
| 1 | 99-885005
|
TRUELOK EVO 3 HOLES POST |
| 1 | 99-885003M
|
TRUELOK EVO BOLT L16.5MM (PACK OF 4) |
| 3 | 99-941640
|
SELF DRILLING XCALIBER CYLINDRICAL SCREW SHAFT D.6mm THREAD 6 mm L 180/40 QC |
| 1 | 99-885002M
|
TRUELOK EVO 8MM HALF PIN FIXATION BOLT (PACK OF 4) |
| 2 | 99-885000M
|
TRUELOK EVO NUT WITH WASHER (PACK OF 5) |


Fracture of the proximal tibia treated with XCaliber Fixator (91000 series) with T-Clamp....
Read MoreDiaphyseal fracture of the tibia treated temporarily with Galaxy UNYCO Diaphyseal Tibia frame and mo...
Read MoreSegmental fracture of the tibial diaphysis treated temporarily with Galaxy UNYCO Diaphyseal Tibia fr...
Read MoreLarge unstable, segmental fracture of the tibial shaft; stabilized using the XCaliber Fixator (91000...
Read MoreLarge unstable, segmental fracture of the tibial shaft; stabilized using the Procallus Fixator (9000...
Read MoreCentronail™ Titanium Tibial Nail
Long diaphyseal segmental fracture of the tibial shaft stabilized using the Centronail Titanium Tibi...
Read MoreDistal tibial fracture stabilized using the XCaliber Fixator (91000 series) with the T-Clamp distall...
Read MoreDistal tibial fracture stabilized using the Procallus Fixator (90000 series) with the Metaphyseal Cl...
Read MoreArticular fracture of the proximal tibia treated with Galaxy Fixation™ system and TL-HEX....
Read MoreFracture of the tibial shaft stabilized using a closed frame with the Galaxy Fixation Gemini™...
Read MoreFoot and Ankle Charcot Reconstruction with External Fixation
Surgical reconstruction of foot and ankle Charcot with external fixation is especially useful in the presence of poor bone quality,Read MoreExpert Tips on How to Medically Diagnose Charcot Arthropathy
The diagnosis of Charcot neuroarthropathy of the foot and ankle can be challenging due to a lack of information inRead MoreThis website is reserved only for Healthcare Professionals and their staff. Therefore, the access to these information is denied to non professional audience.
