THIS INFORMATION IS FOR HEALTHCARE PROFESSIONALS ONLY

3D24

Distal tibial fracture stabilised with TrueLok EVO™

Equipment required
Q.tyCatalogue N.Description
1

99-88007

 

TRUELOK EVO SET RX FOOTPLATE WITH RING D160MM RX STRUTS LONG STERILE

1

99-88020

 

TRUELOK EVO CONN ELEMENT K WIRES CYLINDR PINS SET STERILE

1

99-882160

 

TRUELOK EVO RX 5/8 MODULAR RING D160MM STERILE

1

99-881160

 

TRUELOK EVO RX 3/8 MODULAR RING D160MM

1

99-883160

 

TRUELOK EVO RX FOOTPLATE D160MM

1

99-884160

 

TRUELOK EVO RX FOOT ARCH 160

3

99-886005

 

TRUELOK EVO RX STRUT LONG WITH DYNA

1

99-885006

 

TRUELOK EVO 4 HOLES POST

1

99-885003M

 

TRUELOK EVO BOLT L16.5MM (PACK OF 4)

3

99-941640

 

SELF DRILLING XCALIBER CYLINDRICAL SCREW SHAFT D.6mm THREAD 6 mm L 180/40 QC

1

99-885002M

 

TRUELOK EVO 8MM HALF PIN FIXATION BOLT (PACK OF 4)

3

54-1216

 

TL,WIRE, BAYONET, 1.8MM X 400MM

2

99-885001M

 

TRUELOK EVO WIRE FIXATION BOLT (PACK OF 4)

3

99-885000M

 

TRUELOK EVO NUT WITH WASHER (PACK OF 5)

Operative techniques

TruelokTM EVO Ring Fixation System

Videos
Pin Site Care
TruelokTM EVO Ring Fixation System
Instructions for use

PQ_ETK - TL-HEX Emergency Tab Kit

PQ_EXF - Orthofix External Fixation System

PQ_FRA - TrueLok Forefoot Arch

PQ_ISP - Orthofix Fixation System Medical Devices

PQ_KIF - TL-Hex Kit ID Frame Adult - TL-Hex Kit IF Frame Pediatric

PQ_SCR - Orthofix Bone Screws for External Fixation System

PQ_SUO - Risks Due to the Re-Use of "Single Use" Device

PQ_TLD - TrueLok and TL-HEX Dynamization Module

PQ_TLK - TrueLok External Fixation System

PQ_WTN - TrueLok Wire Tensioner

TruelokTM EVO

Category:

FROM THE BLOG

Post-Operative Management of Deformity Correction Surgery with External Fixation

2023-11-09

The successful outcome of a deformity correction with external fixation surgery relies also on a meticulous post-operative management approach. It is critical to optimal healing and the restoration of functionality. Wound care, pain control, rehabilitation exercises, monitoring of complications, and regular follow-ups are integral to a faster recovery.[1]

Read More
Weight Bearing and Dynamization

2021-11-17

Weigh bearing is considered a significant clinical issue particularly when an external fixator has been applied to a lower limb. If mechanical stability is in fact a mandatory condition for promoting fracture healing, other key components for a full recovery of the bone are early weight bearing and dynamization.

Read More